Inside the 3Xx the GND and AGND are always connected via internal "star-point". This means both GNDs are connected on the circuit board at a speci...
Wed, 19 Aug, 2015 at 11:33 AM
When flashing the ESX_LTp, you should not use the IEC1131 Application and Run Time System settings for the hex file type in Winflash. This will load the pro...
Wed, 19 Aug, 2015 at 3:36 PM
In order to change the UTC time / date on a TC3, execute the following command as one line:
#date 2013.04.03-15:44;hwclock –w This example sets the UTC ti...
Wed, 19 Aug, 2015 at 3:38 PM
3 different files need to be edited on the TC3 to enable wireless lan.
First, log in to the TC3 using the serial port (username root, no password). Navig...
Mon, 28 Sep, 2015 at 12:31 PM
The issue that you are experiencing is caused by the new firmware which corrected a non-CiA conform handling of the PDO mapping. In order to allow changing ...
Wed, 19 Aug, 2015 at 3:56 PM
The supply Voltage for the output driver U(dr) of the BBI 22998 = UB U(dr) = UB
The Voltage drop across the output driver is: ~2.5V Calculation of the ma...
Wed, 19 Aug, 2015 at 3:47 PM
The supply Voltage for the output driver U(dr) of the 14423 is calculated as follows: U(dr) = ~13V when the controller's supply Voltage level UB > 15...
Wed, 19 Aug, 2015 at 3:46 PM
In the PLC configuration, is the memory address of the I/O in question %QD or %ID?? - Q is for output, I is for input. - To change, right click the I/O, sel...
Mon, 17 May, 2021 at 10:26 AM
***Only the IOXp and 3XM/3XL can mask the Rx bus on an individual msg object basis, the older controllers only have the option to mask the entire bus!!!*** ...
Mon, 17 May, 2021 at 9:18 AM